<LOGO>
FM Transmitter Measurement Report
Created: 2024-04-27 07-10-50
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
95.40 MHz 5/5, 37 dBuV R-PLUS
Pilot RDS Phase Difference
0.0 kHz 3.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
6 kHz 10 kHz 15203 0,0132
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -1,01 dBr -0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"R-PLUS " 2424 2 (Affairs) 1 0 0 0 7:10, 27.04.2024
RT
"Analyzy a komentare - deni z domova i ze sveta "
AF EON
91.3, 92.6, 93.3, 93.5, 95.7, 97.9, 98.0, 98.2, 99.5, 101.9, 103.6 MHz -
FM Scope Max at: 10 kHz MIN: 6 kHz % above 77 kHz: 0,0132 Acquired: 2024/04/27 7:10:47 Total samples: 15203 Equivalent time: 0:12:40 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200 300 400
FM Scope MAX: -0,1 dBr MIN: -2,1 dBr AVE: -1,01 dBr % above 0,2 dBr: 0,0 Last value: -1,6 dBr (2024/04/27 7:10:47) 06:56 06:58 07:00 07:02 07:04 07:06 07:08 07:10 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality